====Not Supported by OSCAR==== | ====Not Supported by OSCAR==== | ||
− | Dreamstation 2 (''April 2021 | + | Dreamstation 2 (''New model introduced April 2021. The data is significantly different, so '''the developers need more samples''' in order to add support.'') |
====Fully Supported by Oscar==== | ====Fully Supported by Oscar==== | ||
− | The following machines have been tested and are supported by OSCAR v1.2.0 | + | The following machines have been tested and are supported by OSCAR v1.2.0: |
<br> | <br> | ||
Line 24: | Line 24: | ||
*DreamStation Auto BiPAP (700X110) | *DreamStation Auto BiPAP (700X110) | ||
<br> | <br> | ||
− | '''Dreamstation BiPAP & ASV''' | + | '''Dreamstation BiPAP & ASV''' |
− | + | *DreamStation BiPAP autoSV (900X110, 900X120, 900X150) - ''see note 2 below'' | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | *DreamStation BiPAP autoSV (900X110, 900X120, 900X150) | ||
*DreamStation BiPAP S/T 30 (1030X110) | *DreamStation BiPAP S/T 30 (1030X110) | ||
*DreamStation BiPAP S/T 30 with AAM (1030X150) | *DreamStation BiPAP S/T 30 with AAM (1030X150) | ||
− | *DreamStation BiPAP AVAPS 30 (1130X110) | + | *DreamStation BiPAP AVAPS 30 (1130X110) - ''see note 2 below'' |
*DreamStation BiPAP AVAPS 30 AE (1131X150) | *DreamStation BiPAP AVAPS 30 AE (1131X150) | ||
<br> | <br> | ||
Line 62: | Line 54: | ||
<br> | <br> | ||
'''''Dorma - limited, see note * below''''' | '''''Dorma - limited, see note * below''''' | ||
− | *''Dorma 500 Auto (System One 60 Series) (501V) - limited, see note * below | + | *''Dorma 500 Auto (System One 60 Series) (501V) - limited, see note * below'' |
<br> | <br> | ||
− | ''* NOTE: 200-series and Dorma machines report only settings and hours used. They do not record detailed efficacy data, and therefore should be avoided.'' | + | '''''* NOTE:''' 200-series and Dorma machines report '''only''' settings and hours used. They do not record detailed efficacy data, and therefore should be avoided.'' |
+ | <br><br> | ||
+ | '''''** NOTE 2:''' The 900X and 1130X series machines have a bug in which the maximum <u>mask pressure</u> they report is 15.875 cmH2O. On these machines, refer to the EPAP and IPAP channels to see the correct pressures being delivered. The 1030X machines do not have this bug, and the 1131X machines are currently unknown.'' | ||
== Resmed Machines == | == Resmed Machines == |
Revision as of 17:20, 23 April 2021
Afrikaans /
في الصفحة /
български /
中国 /
臺灣 /
čeština/
Dansk /
Deutsch /
Ελληνικά /
Español /
Filipino /
Français /
עברית /
Magyar /
Italiano /
日本語 /
한국어 /
Nederlands /
Norsk /
Polskie /
Português /
Română /
Pусский /
Suomalainen /
Svenska /
ภาษาไทย /
Türkçe |
Back to OSCAR_Help
OSCAR 1.1.0 supports the devices listed below. Most of the machines listed as Not supported do not provide the necessary data for OSCAR to read. Please note that many machines are known by different names in different markets.
Contents
Philips Respironics Machines
Not Supported by OSCAR
Dreamstation 2 (New model introduced April 2021. The data is significantly different, so the developers need more samples in order to add support.)
Fully Supported by Oscar
The following machines have been tested and are supported by OSCAR v1.2.0:
Dreamstation CPAP & APAP
- DreamStation CPAP (200X110) - limited, see note * below
- DreamStation CPAP Pro (400X110, 400X150)
- DreamStation Go (400G110)
- DreamStation Auto CPAP (500X110, 500X120, 500X130, 500X150)
- DreamStation Go Auto (500G110, 502G150)
- DreamStation BiPAP Pro (600X110)
- DreamStation Auto BiPAP (700X110)
Dreamstation BiPAP & ASV
- DreamStation BiPAP autoSV (900X110, 900X120, 900X150) - see note 2 below
- DreamStation BiPAP S/T 30 (1030X110)
- DreamStation BiPAP S/T 30 with AAM (1030X150)
- DreamStation BiPAP AVAPS 30 (1130X110) - see note 2 below
- DreamStation BiPAP AVAPS 30 AE (1131X150)
System One 60 Series
- REMstar Plus (System One 60 Series) (261CA) - limited, see note * below
- REMstar Pro (System One 60 Series) (460P, 461P, 462P, 461CA)
- REMstar Auto (System One 60 Series) (560P, 561P, 562P, 560PBT)
- BiPAP Pro (System One 60 Series) (660P)
- BiPAP Auto (System One 60 Series) (760P)
- BiPAP autoSV Advanced (System One 60 Series) (960P, 961P)
- BiPAP autoSV Advanced 30 (System One 60 Series) (960T)
- BiPAP S/T 30 (System One 60 Series) (1061T)
- BiPAP AVAPS 30 (System One 60 Series) (1160P)
System One
- REMstar Plus (System One) (251P) - limited, see * note below
- REMstar Pro (System One) (450P, 451P, 452P)
- REMstar Auto (System One) (550P, 551P)
- BiPAP Pro (System One) (650P)
- BiPAP Auto (System One) (750P)
- BiPAP AutoSV Advanced System One (950P, 951P)
C Series
- BiPAP S/T (C Series) (1061401)
Dorma - limited, see note * below
- Dorma 500 Auto (System One 60 Series) (501V) - limited, see note * below
* NOTE: 200-series and Dorma machines report only settings and hours used. They do not record detailed efficacy data, and therefore should be avoided.
** NOTE 2: The 900X and 1130X series machines have a bug in which the maximum mask pressure they report is 15.875 cmH2O. On these machines, refer to the EPAP and IPAP channels to see the correct pressures being delivered. The 1030X machines do not have this bug, and the 1131X machines are currently unknown.
Resmed Machines
Fully Supported by Oscar
The following machines have been tested and are supported by OSCAR v1.1.0
Resmed Airsense 10 and Aircurve 10
- Airsense 10 Elite
- Airsense 10 Autoset
- Airsense 10 AutoSet for Her
- Aircurve 10 S (Lumis 100 VPAP S)
- Aircurve 10 ST (Lumis 150 VPAP ST)
- Aircurve 10 ST-A (Lumis 150 VPAP ST-A)
- Aircurve 10 VAuto
- Aircurve 10 ASV (PaceWave CS)
Resmed S9 Series
- Elite CPAP
- Autoset
- Autoset for Her
- VPAP S
- VPAP Auto
- VPAP ST
- VPAP Adapt (AutoSet CS)
Not Supported by Oscar
- AirStart (all models)
- Airsense 10 CPAP
- AirMini
- S9 CPAP SE
- S9 Escape CPAP
- S9 Escape Auto
- Resmed S8 and earlier series
DeVilbiss
Partly Supported by Oscar
- DV54 Auto
- DV64 CPAP
- DV64 Auto
Fisher & Paykel
Partly supported by Oscar
- Icon
- Icon+
--Note: Fisher & Paykel does not store a "Flow Rate" signal, so no waveform graph, nor analysis is possible, (Events, Pressure, AHI, Snore, Leak Rate, and advanced charts: Resp. Rate, Tidal Volume, Minute Volume, Time at Pressure).
Not Supported by Oscar
- Sleepstyle
Löwenstein / Weinmann
Partly supported by Oscar
- Prisma
- Somnobalance
Apex, BMC, Luna
Not supported by OSCAR
_______________
Pulse Oximeters
Oximetry Wizard
Data from the following pulse oximeters can be imported via OSCAR's Oximetry Wizard:
- Contec CMS-50D+, CMS-50-E, CMS-50E
- Contec CMS-50F, CMS-50H, CMS-50I (v3.7 firmware or later)
- Pulox PO-200/300/400/500
Note: Contec CMS-50F -- the newer version 2 hardware uses a new USB protocol which the OSCAR team has not yet reverse engineered, so currently you need to use the new (Windows-only) Contec software to read the data and create a data file, which apparently uses the same format as the older models. This has not been verified just yet.
The Pulse Ox CMS50F Version 2.0.0 hardware requires the Smart Device Assistant V3.1.0.1. The software can be downloaded at http://www.dlsoftw.com with index code: 01GS4016.
The software's default SpO2 data storage folder in Windows 10 is C:\users\user name\AppData\Local\VirtualStore\Program Files (x86)\Smart Device Assistant v3.1.0\Data. I copy CMS50F SpO2 data files from the default Smart Device Data folder to a new root directory folder named C:\SpO2_Data. Oscar will import the SpO2 data files directly from the C:\SpO2_Data folder. You must first have Oscar import your machine's sleep data file from your SD Card prior to importing the corresponding SpO2 data file from the same time frame.
Manual Import
Beginning in OSCAR 1.1.0, the following pulse oximeters are imported via OSCAR's Data > Import Viatom Data... menu. See Viatom File Import for how to download and import their data files.
- Viatom/Wellue SleepU
- Viatom/Wellue O2Ring
_______________
Sleep Monitors
Data from the following sleep monitors can be imported via the Data menu.
- Zeo
- Dreem
- Somnopose (iPhone sleep position monitor)
Donate to Apnea Board